Vertical Winding Machine
- Model:
- 800~1600
Detail Specifications / Descriptions
* This machine is designed for the large 345KVA transformer which is unable to wind the copper wire when using the horizontal winding machine because of the falling problem during wire-winding. This machine which is vertical therefore solves the problem. It’s operated by single person as well.
* Specification:
Coil Max. O.D. O2300mm
Coil Adjustment I.D. O800mm ~ O1600mm
Coil Max. High H2500mm
Coiled Weight 10, 000kg
Servo Motor 3Φ220V 18KW
Power 3Φ220V 50 / 60Hz 100A
old Underground (Pit type) 6 meters